Join our Mailing List    

Your ultimate source for explosion-proof air conditioners, building pressurization units, gas phase filtration systems, and fully integrated wall, pad and split system hazardous and industrial climate control solutions!
Products Services Contacts Us About Us
News      Testimonials
Introduction Product Applications Unit Case Styles & Materials Unit Configurations Standard Features Optional Features Specs, Certification & Warranty Unit Accessories Technical Bulletins Model Number Matrix On-Line Inquiries

Refinery Area Roof Mount Air Conditioners & Heat Pumps

Model RAC & RHP
Roof Mount
Air Conditioners & Heat Pumps

Specs, Certification & Warranty

ETL listed explosion-proof roof mount air conditioners and heat pumps, hazardous location roof mount hvac units, listed roof mount air conditoners and heat pumps, certified roof mount hvac units, hazardous location explosion proof roof-mount air conditioners and heat pumps

Clearance Requirements

The following data and diagram indicate "free space" clearances around our units that are essential to proper operation.
Please contact a Bebco Sales Associate for more information or clarifications, if required.

 
Model RAC & RHP Hazardous Location Air Conditioner & Heat Pump Clearance Requirements

Click Image to Enlarge

Minimum clearances are critical
to ensure proper unit operation

BEST PRACTICES
Provide minimum external clearances on the left and right
sides and rear side of a Model RAC or RHP Unit for inlet air
and on the rear side of a Unit for exhaust air that is
passing through the condenser compartment.


Provide minimum internal clearance for recirculating
airflow within the room or building.

Minimum of 1 Inch between the left and right sides
of Model RAC & RHP Units and any obstructions

Minimum of 8 Inches from rear side of Model RAC & RHP Units
to any vertical 90 to 45 degree surface obstruciton; or
Minimum of 4 Inches from rear side of Model RAC & RHP Units
to any angled 45 degree or less surface obstruciton





Bebco Environmental Controls Corporation
Physical Address: 4725 Lawndale Street, La Marque, Texas 77568
Mailing Address: P.O. Box 68 Hitchcock, Texas 77563
Phone: (844) 397-4822     |   Fax: (409) 935-5819
Office Hours:
 8 AM to 5 PM CST, Monday - Friday
Please visit this site for NFPA 496 UL Classified Enclosure Purging Systems:
Best Purging Systems Corporation

  |     |     |  
Terms of Use   |     |   Privacy Policy   |   Terms of Sale
Product Warranties   |   Return Policy & Form   |   Product Registration Form   |   Site Map

Copyright © 2019 – All Rights Reserved      Click the Terms of Use Link above for more information.